Paper | Title | Page |
---|---|---|
TUPTS113 | Microwave Thermionic Electron Gun for Synchrotron Light Sources | 2189 |
|
||
Funding: This work was supported by the U.S. Department of Energy, Office of Basic Energy Science, under contracts DE-SC0015191 and DE- AC02-06CH11357. Thermionic RF guns are the source of electrons used in many practical applications, such as drivers for synchrotron light sources, preferred for their compactness and efficiency. RadiaBeam Technologies has developed a new thermionic RF gun for the Advanced Photon Source at Argonne National Laboratory, which would offer substantial improvements in reliable operations with a robust interface between the thermionic cathode and the cavity, as well as better RF performance, compared to existing models. This improvement became possible by incorporating new pi-mode electromagnetic design, robust cavity back plate design, and a cooling system that will allow stable operation for up to 1 A of beam current and 100 Hz rep rate at 1.5 μs RF pulse length, and 70 MV/m peak on-axis field in the cavity. In this paper, we discuss the electromagnetic and engineering design of the cavity and provide the test results of the new gun. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-TUPTS113 | |
About • | paper received ※ 30 April 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THYYPLM3 | High-Charge Injector for on-Axis Injection Into A High-Performance Storage Ring Light Source | 3423 |
|
||
Funding: Work supported by U. S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357. Next-generation, high-performance storage ring light sources based on multibend achromat optics will require on-axis injection because of the extremely small dynamic aperture. Injectors will need to supply full-current bunch replacement in the ring with high single-bunch charge for swap-out. For upgrades of existing light sources, such as the Advanced Photon Source Upgrade (APS-U), it is economical to retain the existing injector infrastructure and make appropriate improvements. The challenges to these improvements include achieving high single-bunch charge in the presence of instabilities, beam loading, charge stability and reliability. In this paper, we discuss the rationale for the injector upgrades chosen for APS-U, as well as backup and potential alternate schemes. To date, we have achieved single-bunch charge from the injectors that doubles the original design value, and have a goal to achieve about three times the original design value. |
||
![]() |
Slides THYYPLM3 [1.499 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THYYPLM3 | |
About • | paper received ※ 15 May 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |