Paper |
Title |
Page |
TUPMP006 |
Cryogenic Tests of the SPIRAL2 LINAC Systems |
1240 |
|
- A. Ghribi, P.-E. Bernaudin, R. Ferdinand, A.V. Vassal
GANIL, Caen, France
|
|
|
Two full cool-down of the SPIRAL2 superconducting LINAC have been performed in 2017 and 2018 respectively, followed by a total of around 5 months of tests at 4 K. Several cool-down strategies were tested, in order to minimize 100 K effect on the SC cavities. Helium bath regulations (level and pressure) have been tested and optimized. Effects of pressure instabilities and coupling with the cryogenic plant have also been observed. Cryogenic performances of each cryomodule have been measured. Low-level RF measurements were also performed on all cavities and showed unidentified modulations at frequencies around 5Hz. These turned out to be thermoacoustic oscillations (TAO) on the cryogenic lines, which generate important pressure instabilities. Several solutions to remove TAO and cure these instabilities have been tested and one has been successfully deployed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-TUPMP006
|
|
About • |
paper received ※ 14 May 2019 paper accepted ※ 21 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|