Paper | Title | Page |
---|---|---|
THPVA096 | Development of 11C+ Ion Source for Reacceleration With HIMAC for Real-Time Observation of Dose Distribution | 4686 |
|
||
In order to improve the precision of dose distribution in a patient's body in the case of carbon therapy, realtime measurement of the dose distribution with the use of the so called OPEN PET is desirable. For realization of such a treatment, usage of isotope separator online scheme based on target fragment might be inevitable to keep the needed S/N ratio. From the above requirement, we have been developing 1+ ion source of positron emitting 11C+ ions*, which will be charge breeded before injection into the injector LINAC of the HIMAC. 11C+ ion is to be produced by a high intensity proton beam from a cyclotron. In the real process, a small cyclotron like HM20 might provide the proton beam, but at the development stage, we are planning investigation utilizing proton beam from the AVF cyclotron existing at NIRS with K-number of 110. In the present paper, the total scheme of radioactive ion re-acceleration will be described together with the recent ion source development.
* K. Katagiri et al., Review of Scientific Instruments 87, 02B509 (2016) |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA096 | |