Paper |
Title |
Page |
TUPIK001 |
Upgrade of the Two-Screen Measurement Setup in the AWAKE Experiment |
1682 |
SUSPSIK033 |
|
|
- M. Turner
TUG/ITP, Graz, Austria
- V. Clerc, I. Gorgisyan, E. Gschwendtner, S. Mazzoni, A.V. Petrenko
CERN, Geneva, Switzerland
|
|
|
The AWAKE project at CERN uses a self-modulated §I{400}{GeV/c} proton bunch to drive GV/m wakefields in a §I10{m} long plasma with an electron density of npe = 7 × 1014 \rm{electrons/cm}3. We present the upgrade of a proton beam diagnostic to indirectly prove that the bunch self-modulated by imaging defocused protons with two screens downstream the end of the plasma. The two-screen diagnostic has been installed, commissioned and tested in autumn 2016 and limitations were identified. We plan to install an upgraded diagnostics to overcome these limitations.
|
|