Author: Morishita, T.
Paper Title Page
TUPVA096 Detection of H0 Particles in MEBT2 Chicane of J-PARC Linac 2308
 
  • J. Tamura, H. Ao, T. Maruta, A. Miura, T. Morishita, K. Okabe, M. Yoshimoto
    JAEA/J-PARC, Tokai-mura, Japan
  • K. Futatsukawa, T. Miyao
    KEK, Ibaraki, Japan
  • Y. Nemoto
    Nippon Advanced Technology Co., Ltd., Tokai, Japan
 
  In the Japan Proton Accelerator Research Complex (J-PARC), H0 particles generated by collisions of accelerated H beams with residual gases are considered as one of the key factors of the residual radiation in the high energy accelerating section of the linac. To diagnose the H0 particles, the new beam line for analyzing H0 and H particles was installed in the second medium energy beam transport (MEBT2), which is the matching section from the separated-type drift tube linac (SDTL) to the annular-ring coupled structure linac (ACS). The analysis line consists of four dipole magnets for giving the H beam chicane orbit, and a wire scanner monitor (WSM) for measuring the horizontal shift of the H beam. To detect the H0 particles, a carbon plate is installed to the WSM. In the beam commissioning, we detected the signals of H0 particles penetrating the plate and observed the transition of the signal with various vacuum condition in the SDTL section.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPVA096  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPIK039 Multipactor Problem of J-PARC SDTL 4184
 
  • T. Ito, T. Morishita, J. Tamura
    JAEA/J-PARC, Tokai-mura, Japan
  • K. Nanmo, T. Sugimura
    KEK, Ibaraki, Japan
 
  We have suffered from multipactor problem of some SDTL after the Great East Japan Earthquake. As a designed operating rf power of the SDTL is in the multipactor region, we had to operate at higher power of the designed one. From the result of the simulation and the observation of the SDTL cavity, it became clear that the multipactor occurred on the inner surface of the cavity. We think that one of the cause of the maultipactor is the contamination on the inner surface of the cavity, we performed the cleaning of the inner surface of the cavity by using acetone. The cleaning was very effective and the multipactor region was reduced dramatically or disappeared. The multipactor problem has not occurred since then.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPIK039  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)