Author: Miki, N.
Paper Title Page
MOPIK035 New Injection Scheme of J-PARC Rapid Cycling Synchrotron 579
 
  • K. Yamamoto, H. Harada, H. Hotchi, J. Kamiya, P.K. Saha, T. Takayanagi, M. Yoshimoto
    JAEA/J-PARC, Tokai-mura, Japan
  • N. Miki, O. Takeda
    Nippon Advanced Technology Co., Ltd., Tokai, Japan
 
  The 3-GeV Rapid Cycling Synchrotron (RCS) of Japan Proton Accelerator Research Complex (J-PARC) aims to deliver 1-MW proton beam to the neutron target and Main Ring synchrotron (MR). Present beam power of RCS is up to 500-kW and the higher radiation doses were concentrated in the injection area. These activations were caused by the interaction between the foil and the beam. To reduce the worker dose near the injection point, we have studied new design of the injection scheme to secure enough space for radiation shielding and bellows. In the new system, two of four injection pulse bump magnets are replaced and we are able to ensure the additional 500 mm space at the injection foil .  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPIK035  