Paper |
Title |
Page |
MOPVA039 |
Manufacturing and Validation Tests of IFMIF Low-Beta HWRs |
942 |
|
- G. Devanz, F. Éozénou, L. Maurice, P. Sahuquet, C. Servouin
CEA/DSM/IRFU, France
- N. Bazin, P. Carbonnier, P. Charon, G. Disset, P. Hardy, E. Jacques, O. Piquet, D. Roudier
CEA/IRFU, Gif-sur-Yvette, France
- J.K. Chambrillon, T. Percerou
CEA/DRF/IRFU, Gif-sur-Yvette, France
|
|
|
The IFMIF accelerator aims to provide an accelerator-based D-Li neutron source to produce high intensity high energy neutron flux to test samples as possible candidate materials to a full lifetime of fusion energy reactors. A prototype of the low energy part of the accelerator is under construction at Rokkasho in Japan. It includes one cryomodule containing 8 half-wave resonators (HWR) operating at 175 MHz .The first manufactured HWR has passed low power tests at 4.2K in vertical cryostat succesfully and exceeds the specifications. It has also been tested in the dedicated horizontal Sathori cryostat equiped with its cold tuning system. The serial production and qualification tests of the 8 cavities which will eventually equip the cryomodule are carried out in parallel. In this paper, we focus on the HWR preparation and test results and give a status of the manufacturing activities.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA039
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
MOPVA041 |
Vertical Test Results on ESS Medium and High Beta Elliptical Cavity Prototypes Equipped with Helium Tank |
948 |
|
- E. Cenni
CEA/IRFU, Gif-sur-Yvette, France
- P. Bosland, G. Devanz, F. Éozénou, X. Hanus, L. Maurice, F. Peauger, J. Plouin, D. Roudier, C. Servouin
CEA/DSM/IRFU, France
- G. Costanza
Lund University, Lund, Sweden
- C. Darve
ESS, Lund, Sweden
|
|
|
The ESS elliptical superconducting Linac consists of two types of 704.42 MHz cavities, medium and high beta, to accelerate the beam from 216 MeV (spoke cavity Linac) up to the final energy at 2 GeV. The last Linac optimization, called Optimus+, has been carried out taking into account the limitations of SRF cavity performance (field emission). The medium and high-beta parts of the Linac are composed of 36 and 84 elliptical cavities, with geometrical beta values of 0.67 and 0.86 respectively. This work presents the latest vertical test results on ESS medium and high beta elliptical cavity prototypes equipped with helium tank. We describe the cavity preparation procedure from buffer chemical polishing to vertical test.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA041
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|