Author: Kojima, Y.
Paper Title Page
TUPAB006 Achievement of Stable Pulsed Operation at 31 MV/m in the STF-2 Cryomodule for the ILC 1308
 
  • Y. Yamamoto, T. Dohmae, M. Egi, K. Hara, T. Honma, E. Kako, Y. Kojima, T. Konomi, N. Kota, T. Kubo, T. Matsumoto, T. Miura, H. Nakai, K. Nakanishi, G.-T. Park, T. Saeki, H. Shimizu, T. Shishido, T. Takenaka, K. Umemori
    KEK, Ibaraki, Japan
 
  In the Superconducting RF Test Facility (STF) in KEK, the cooldown test for the STF-2 cryomodule with 12 cavities has been done totally three times since 2014. In 2016, the 3rd cooldown test for the STF-2 cryomodule including the capture cryomodule with 2 cavities, which was used for Quantum Beam Project in 2012, was successfully done. The main purpose is the vector-sum operation with 8 cavities at average accelerating gradient of 31 MV/m as the ILC specification, and the others are the measurement for Lorenz Force Detuning (LFD) and unloaded Q value, and Low Level RF (LLRF) study, etc. During 8 cavities operation, piezo actuators were used for the compensation of LFD, and the feed-forward and vector-sum control system by LLRF worked perfectly for keeping the lowest forward power and the stable flat-top of accelerating gradient. In this paper, the result for the STF-2 cryomodule in the 3rd cooldown test will be presented in detail.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB006  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)