Author: Karataev, P.
Paper Title Page
MOPAB111 Diffraction Radiation for Non-Invasive, High-Resolution Beam Size Measurements in Future Linear Colliders 381
SUSPSIK079   use link to see paper's listing under its alternate paper code  
 
  • M. Bergamaschi, R. Kieffer, T. Lefèvre, S. Mazzoni
    CERN, Geneva, Switzerland
  • A. Aryshev, N. Terunuma
    KEK, Ibaraki, Japan
  • M. Bergamaschi, P. Karataev, K.O. Kruchinin
    JAI, Egham, Surrey, United Kingdom
  • M. Bergamaschi, P. Karataev, K.O. Kruchinin
    Royal Holloway, University of London, Surrey, United Kingdom
 
  Next generation linear colliders such as the Compact Linear Collider (CLIC) or the International Linear Collider (ILC) will accelerate particle beams with extremely small emittance. The high current and small size of the beam (micron-scale) due to such small emittance require non-invasive, high-resolution techniques for beam diagnostics. Diffraction Radiation (DR), a polarization radiation that appears when a charged particle moves in the vicinity of a medium, is an ideal candidate being non-invasive and allowing beams as small as a few tens of microns to be measured. Since DR is sensitive to beam parameters other than the transverse profile (e.g. its divergence and position), preparatory simulations have been performed with realistic beam parameters. A new dedicated instrument was installed in the KEK-ATF2 beam line in February 2016. At present DR is observed in the visible wavelength range, with an upgrade to the ultraviolet (200nm) planned for spring 2017 to optimize sensitivity to smaller beam sizes. Presented here are the latest results of these DR beam size measurements and simulations.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB111  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB126 Applications of Metamaterials for Particle Beam Diagnostics 425
SUSPSIK080   use link to see paper's listing under its alternate paper code  
 
  • T.G. Vaughan, P. Karataev
    JAI, Egham, Surrey, United Kingdom
  • V. Antonov
    Royal Holloway, University of London, Surrey, United Kingdom
  • V.V. Soboleva
    RASA Center in Tomsk, Tomsk, Russia
 
  Funding: The work was supported by the Leverhulme Trust through the International Network Grant (IN-2015-012) and the European Union Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No 655179 and Russian Governmental Program 'Nauka', N: 0.1656.2016.
Modern and future accelerators, such as linear colliders and X-ray Free Electron Lasers (X-FELs), will be capable of producing femtosecond and sub-femtosecond electron bunches with unprecedented intensity. Non-invasive beam diagnostics will be an integral component of such machines. A new non-destructive method, which employs a Left Handed Metamaterial (LHM), is promising as it provides additional flexibility in the generation and manipulation of radiation compared to techniques which use conventional materials. Simulations of the interaction of a photon beam with the LHM target have been performed using CST Microwave Studio. The range over which the frequency responce is negative can be tuned to the bunch length requirements by varying the parameters of the unit cell such as: the dimensions of the rings and the number of slits in each ring. Simulations have also been performed using Particle Studio on the interaction of an electron beam with the LHM. With a flexible resonance in the terahertz range, this material not only offers applications for ultra short bunch length measurements, but it also opens up the possibility to be used to generate coherent terahertz radiation.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB126  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB138 Comparison of Optical Transition Radiation Simulations and Theory 455
SUSPSIK082   use link to see paper's listing under its alternate paper code  
 
  • J. Wolfenden, R.B. Fiorito, C.P. Welsch
    Cockcroft Institute, Warrington, Cheshire, United Kingdom
  • M. Bergamaschi, P. Karataev, K.O. Kruchinin
    JAI, Egham, Surrey, United Kingdom
  • M. Bergamaschi, P. Karataev, K.O. Kruchinin
    Royal Holloway, University of London, Surrey, United Kingdom
  • M. Bergamaschi, R. Kieffer, T. Lefèvre
    CERN, Geneva, Switzerland
  • R.B. Fiorito, C.P. Welsch, J. Wolfenden
    The University of Liverpool, Liverpool, United Kingdom
 
  The majority of optical diagnostics currently used will not stand up to the requirements of the next generation of particle accelerators. Current methodologies need innovation to be able to reach the sub-micrometre resolution and sensitivity that will be required. One technique that has the potential to meet these requirements is optical transition radiation (OTR) imaging. A new algorithm is proposed which incorporates OTR theory, optical effects and beam distribution. This algorithm takes an existing method used for beam imaging and pushes the limits resolution beyond that normally attainable. In doing so, it can provide a reliable and economical diagnostic for future accelerators. A discussion on further applications of the algorithm is also presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB138  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPVA018 Drive-Witness Acceleration Scheme Based on Corrugated Dielectric mm-Scale Capillary 3292
 
  • K. Lekomtsev, S.T. Boogert, P. Karataev, A. Lyapin
    JAI, Egham, Surrey, United Kingdom
  • A. Aryshev, M. Shevelev, N. Terunuma, J. Urakawa
    KEK, Ibaraki, Japan
  • A.A. Tishchenko
    MEPhI, Moscow, Russia
 
  Funding: This project has received funding from the European Union Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No 655179.
In this paper, we investigate a corrugated mm-scale capillary as a compact accelerating structure in a drive-witness acceleration scheme, and suggest a methodology to measure acceleration of a witness bunch. Two typical measurements and the energy gain in a witness bunch as a function of the distance between bunches are discussed. A corrugated capillary is considered as an accelerator/decelerator with an adjustable wakefield pattern depending on a transverse beam position.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-WEPVA018  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB118 Cherenkov Diffraction Radiation From Long Dielectric Material: An Intense Source of Photons in the NIR-THz Range 400
 
  • T. Lefèvre, M. Bergamaschi, O.R. Jones, R. Kieffer, S. Mazzoni
    CERN, Geneva, Switzerland
  • M.G. Billing, J.V. Conway, J.P. Shanks
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
  • L.M. Bobb
    DLS, Oxfordshire, United Kingdom
  • P. Karataev
    Royal Holloway, University of London, Surrey, United Kingdom
 
  This paper presents the design on the Cornell Electron Storage Ring (CESR) of an experimental set-up to meas-ure incoherent Diffraction Cherenkov Radiation (DChR) produced in a 2 cm long SiO2 radiator by a 2.1 GeV elec-tron beam. The electron beam is circulating at a distance of few mm from the edge of the radiator and the DChR photon output power is expected to be significantly higher than the diffraction radiation power emitted from a metal-lic slit of similar aperture. The radiator design and the detection set-up are presented in detail together with sim-ulations describing the expected properties of the emitted DChR in terms of light intensity and spectral bandwidth. Finally, potential applications of DChR are discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB118  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)