Author: Iijima, H.
Paper Title Page
TUPAB059 Study on CsKSb Photocathode for the RF Electron Gun 1456
SUSPSIK022   use link to see paper's listing under its alternate paper code  
 
  • H. Ono, J. Miyamatsu, M. Washio
    Waseda University, Tokyo, Japan
  • H. Iijima
    Tokyo University of Science, Tokyo, Japan
  • K. Sakaue
    Waseda University, Waseda Institute for Advanced Study, Tokyo, Japan
 
  At Waseda University, we have been developing a Cs-Te photocathode S-band RF electron gun and application experiments of the electron beam. On the experiments, charge amount is important factor, which strongly depends on laser power and photocathode quality. At present, we are studying CsKSb photocathode to increase the charge amount of an electron beam generated from the RF-Gun. As a result of using CsKSb photocathode in the RF-cavity, we obtained as much charge as using Cs-Te photocathode but the lifetime was shorter than that of Cs-Te. In order to lengthen the photocathode lifetime, we tried to coat a protective film on CsKSb photocathode surface and investigated its robustness for poor vacuum condition that simulates cathode transportation and usage in the RF-Gun. In this conference, we report current status of fabricating coated photocathode and future prospects.
A. Buzulutskov et al. The protection of K-Cs-Sb photocathodes with CsBr films Nuclear Instruments and Methods in Physics Research A 400 (1997) 173-176
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB059  