Author: Huneck, S.
Paper Title Page
TUPVA069 Test of a High Power Room Temperature CH DTL Cavity 2237
 
  • N.F. Petry, S. Huneck, K. Kümpel, H. Podlech, U. Ratzinger, M. Schwarz
    IAP, Frankfurt am Main, Germany
 
  The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum (FRANZ) is planned to deliver ultra-short neutron pulses at high intensities and repetition rates. As part of FRANZ a 175 MHz room temperature 5-gap CH DTL cavity was designed and built. Its main task will be focusing the particle bunch longitudinally at 2 MeV particle energy. Furthermore the CH cavity can also be used to increase the energy as well as decrease it by 0.2 MeV. The rebuncher and its cooling system is optimized to work with a 5 kW amplifier. The amplification system is intended to provide continuous power (cw mode). Due to its operating parameters being nearly identical to the requirements of the MYRRHA (Multi-purpose hYbrid Research Reactor for High-tech Applications) Project, experience for future cavity designs was gained. This includes considerations concerning cooling with use of a 12 kW amplifier. The recent results of conditioning and high power tests will be presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPVA069  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)