Author: Hokonohara, H.
Paper Title Page
MOPVA071 Press Forming Tests of Superconducting Spoke Cavity for Laser Compton Scattered Photon Sources 1031
 
  • M. Sawamura, R. Hajima
    QST, Tokai, Japan
  • H. Hokonohara, Y. Iwashita, H. Tongu
    Kyoto ICR, Uji, Kyoto, Japan
  • T. Kubo, T. Saeki
    KEK, Ibaraki, Japan
 
  We are developing the superconducting spoke cavity for laser Compton scattered (LCS) photon sources. We adopt the superconducting spoke cavity for electron beam drivers to realize a wide use of LCS X-ray and '-ray sources in academic and industrial applications. The spoke cavity can make the accelerator more compact than an elliptical cavity because the cavity size is small at the same frequency and the packing factor is good by installing couplers on outer conductor. Though our proposal design for the photon source consists of the 325 MHz spoke cavities in 4K operation, we are fabricating the half scale model of 650 MHz spoke cavity in order to accumulate our cavity production experience by effective utilization of our limited resources. Since the spoke has more complicated structure than an elliptical cavity, we performed press forming tests for the half spoke and estimated the formed shapes with 3-dimensional measurement.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA071  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPVA075 Development of High Sensitive X-Ray Mapping for SC Cavities 1040
 
  • H. Tongu, H. Hokonohara, Y. Iwashita
    Kyoto ICR, Uji, Kyoto, Japan
  • R.L. Geng, A.D. Palczewski
    JLab, Newport News, Virginia, USA
  • H. Hayano, T. Kubo, T. Saeki, Y. Yamamoto
    KEK, Ibaraki, Japan
  • H. Oikawa
    Utsunomiya University, Utsunomiya, Japan
 
  We developed an X-ray mapping system sX-map for superconducting cavities. The sensors are inserted under the stiffener rings between cavity cells, whose locations are close to the iris areas. The whole circuits are im-mersed in liquid He and the multiplexed signals reduces the number of cables to the room temperature region. sX-map has the advantages in its compact size, low cost and simple setup for nondestructive inspections. The sX-map system detected X-rays from field emissions in vertical RF tests of ILC 9-cell cavities at Jefferson Lab (JLab) and KEK. sX-map showed an excellent performance in the meas-urement test at JLab, it exhibited a high sensitivity com-pared with an the fixed diode rings colocated at irises and ion chamber located out side of the vertical test cryostat.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA075  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)