MOPAB110 Comparison of Transverse Emittance Measurements in the LHC 377
 
  • M. Hostettler, R. Alemany-Fernández, F. Alessio, M. Ferro-Luzzi, K. Fuchsberger, G. Iadarola, R. Matev, S. Papadopoulou, Y. Papaphilippou, G. Papotti, G. Trad
    CERN, Geneva, Switzerland
  • F. Antoniou
    The University of Liverpool, Liverpool, United Kingdom
  • G.R. Coombs
    University of Glasgow, Glasgow, United Kingdom
  • T.B. Hadavizadeh
    Oxford University, Physics Department, Oxford, Oxon, United Kingdom
 
  Transverse emittance measurement in a collider is of crucial importance for understanding beam dynamics observations and evaluating the machine performance. Devices measuring the beam emittance face the challenge of dealing with considerable systematic errors that can compromise the quality of the measurement. Having different instruments or techniques that provide beam size estimations in order to compare the outcome and give an unbiased value of the emittance is very important in a collider. The comparison of the different results is as well very useful to identify possible problems in a given equipment which could remain unnoticed if such device is the only source of emittance reconstruction. In the LHC several of these instruments and techniques are available; wire scanners, synchrotron light monitors, emittance reconstruction from transverse convolved beam sizes extracted from luminosity scans at the LHC collision points and from beam-gas imaging in the vertex detector of the LHCb experiment. Those systems are briefly presented in this paper together with the comparison of the emittances reconstructed by each of them during physics production over the 2016 LHC run.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB110  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB130 Cross-Calibration of the LHC Transverse Beam-Profile Monitors 437
 
  • R. Alemany-Fernández, F. Alessio, A. Alexopoulos, C. Barschel, F.S. Carlier, J.M. Coello de Portugal, M. Ferro-Luzzi, A. Garcia-Tabares, M. Hostettler, O. Karacheban, E.H. Maclean, R. Matev, T. Persson, P.K. Skowroński, R. Tomás, G. Trad, S. Vlachos, B. Würkner
    CERN, Geneva, Switzerland
  • G.R. Coombs
    EPFL, Lausanne, Switzerland
  • T.B. Hadavizadeh
    Oxford University, Physics Department, Oxford, Oxon, United Kingdom
  • M. Hofer
    TU Vienna, Wien, Austria
  • L. van Riesen-Haupt
    University of Oxford, Oxford, United Kingdom
 
  Calibration of a transverse beam profile monitor is of fundamental importance to guarantee the best possible accuracy and reliability of the instrument over time. In LHC the calibration standard for transverse-profile measurements are the wire scanners. Other profile monitors such as beam synchrotron light telescopes and interferometers are calibrated with respect to them. Additional information about single-bunch sizes can be obtained from beam-gas imaging in the LHCb vertex detector, from the transverse convolved beam sizes extracted from luminosity scans at the collision points, and from the evolution of the luminous-region parameters as reconstructed by ATLAS and CMS inner tracker detectors during such scans. For the first time in LHC, a dedicated cross-calibration of all the above-mentioned systems was carried out with beam in 2016. Additionally, dedicated optics measurements were also performed in order to determine with the highest possible accuracy the amplitude function at the interaction points and at the position of the profile monitors. Results of these measurements are presented in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB130  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB131 Transverse Emittance Measurements Using LHCb's Beam-Gas Interactions 441
 
  • T.B. Hadavizadeh
    Oxford University, Physics Department, Oxford, Oxon, United Kingdom
  • R. Alemany-Fernández, F. Alessio, C. Barschel, G.R. Coombs, M. Ferro-Luzzi, R. Matev
    CERN, Geneva, Switzerland
 
  Measurements of the transverse beam emittance are of great importance at particle accelerators such as the LHC in order to monitor, understand and improve the performance of the machine. A number of profile monitors at the LHC are capable of measuring the transverse emittance from a range of different processes including wire scanners and beam synchrotron light monitors, each having advantages and shortcomings. It is possible additionally to measure the beam profiles using interaction vertices reconstructed in LHCb's vertex locator (Velo). Interactions between colliding beam particles and between beam particles and residual gas nuclei are used to build up a picture of the beam profiles. To guarantee the reliability and quality of the different emittance measurements, a dedicated cross-calibration was performed during a machine development period in October 2016. The results obtained with the LHCb Velo during this cross-calibration are presented here.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB131  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)