Author: Gerhard, P.
Paper Title Page
TUPVA057 Design Study for a Prototype Alvarez-Cavity for the Upgraded Unilac 2205
 
  • M. Heilmann, X. Du, P. Gerhard, L. Groening, M. Kaiser, S. Mickat, A. Rubin
    GSI, Darmstadt, Germany
  • A. Seibel
    IAP, Frankfurt am Main, Germany
 
  The design study describes the prototype Alvarez-tank of the new post-stripper of the UNILAC. A prototype with 17 drift tubes (including quadrupole singulets) of 3 m of total length and 2 m of diameter will be manufactured. This cavity features new drift tube shape profiles to provide for high shunt impedance at a maximum electric surface field of 1 Ek. Additionally, it allows realization and high power testing of an optimized stem configuration for field stabilization. In case of successful tuning and long-term operation at high power level, it shall be used as a first of series cavity of the new UNILAC post-stripper DTL.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPVA057  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPIK021 Structural Mechanical Analysis of 4-Rod RFQ Structures in View of a Newly Revised CW RFQ for the HLI at GSI 4142
SUSPSIK091   use link to see paper's listing under its alternate paper code  
 
  • D. Koser, H. Podlech
    IAP, Frankfurt am Main, Germany
  • P. Gerhard, L. Groening
    GSI, Darmstadt, Germany
  • O.K. Kester
    TRIUMF, Vancouver, Canada
 
  Funding: BMBF Contr. No. 05P15RFRBA
The High Charge State Injector (HLI) at the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany, serves as one of the two injector linacs for the UNILAC as well as dedicated injector for the upcoming cw linac project for super heavy element research. As the front end of the HLI is planned to be upgraded for cw operation a newly revised cw capable RFQ structure with an operating frequency of 108 MHz is required. The existent 4-rod structure, which was commissioned at the HLI in 2010, suffers from severe modulated rf power reflections originating from mechanical oscillations of the electrodes that both limit the achievable performance and impede stable operation*. Besides preceding vibration measurements that were done by GSI using a laser vibrometer**, the structural mechanical behavior of the 4-rod geometry was extensively analyzed using ANSYS Workbench. Thereby the crucial mechanical eigenmodes could be identified and their impact on the rf properties was investigated by simulations using CST MWS. A completely newly revised 4-rod RFQ design with optimized structural rigidity was developed of which a 6-stem prototype is currently being manufactured.
*P. Gerhard et al., Experience With a 4-Rod CW Radio Frequency Quadrupole, LINAC12, THPLB07
**P. Gerhard et al., In Situ Measurements of Mechanical Vibrations of a 4-Rod RFQ at GSI, LINAC14, TUPP057
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPIK021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)