Author: Cullinan, F.J.
Paper Title Page
MOPVA004 Operating Simultaneously Two In-Vacuum Canted Undulators in Synchrotron SOLEIL 851
 
  • L.S. Nadolski, Y.-M. Abiven, P. Brunelle, N. Béchu, M.-E. Couprie, F.J. Cullinan, X. Delétoille, M. El Ajjouri, C. Herbeaux, N. Hubert, N. Jobert, M. Labat, J.-F. Lamarre, A. Lestrade, A. Loulergue, O. Marcouillé, P. Monteiro, A. Nadji, R. Nagaoka, D. Pédeau, P. Rommeluère, K.T. Tavakoli, M. Valléau, J. Vétéran
    SOLEIL, Gif-sur-Yvette, France
  • C. Benabderrahmane
    ESRF, Grenoble, France
 
  Each long SOLEIL beamline, ANATOMIX and Nanoscopium, takes a photon beam from an in-vacuum undulator with a minimum gap of 5.5 mm. The canted radiation sources are installed in a long straight section of the storage ring. The first closure of both undulators led to the severe damage of the downstream undulator in 2011. The reason for this incident has been investigated and clearly identified. A long-term project has enabled us to find a technical solution for a simultaneous operation of both undulators. A special angle fast interlock was designed and a dedicated photon absorber has been introduced at the entrance of the second undulator while keeping the impact on the beam performance as low as possible. The main technical steps will be reported with an interim solution put in place in spring 2015 and a final solution deployed and validated in May 2016.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA004  