Author: Cheng, C.
Paper Title Page
TUPVA105 Development Progress of the 7MeV Linac Injector for the 200MeV Synchrotron of Xi'an Proton Application Facility 2336
 
  • Q.Z. Xing, C.B. Bi, C. Cheng, D. Dan, C.T. Du, T.B. Du, X. Guan, Q.K. Guo, Y. Lei, K.D. Man, C.-X. Tang, R. Tang, D. Wang, X.W. Wang, H.Y. Zhang, S.X. Zheng
    TUB, Beijing, People's Republic of China
  • W.Q. Guan, Y. He, J. Li
    NUCTECH, Beijing, People's Republic of China
  • E.Y. Qu, B.C. Wang, Z.M. Wang, Y. Yang, C. Zhao
    State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Shannxi, People's Republic of China
 
  We present, in this paper, the development progress of the 7MeV Linac for the 200MeV synchrotron of the Xi'an Proton Application Facility (XiPAF). The 7 MeV linac injector is composed of the 50 keV negative hydrogen ion source, Low Energy Beam Transport line (LEBT), 3 MeV four-vane type Radio Frequency Quadrupole (RFQ) accelerator, 7 MeV Alvarez-type Drift Tube Linac (DTL), and the corresponding RF power source system. The 2.45 GHz microwave-driven Cesium-free Electron Cyclotron Resonance (ECR) source and LEBT will be commissioned in this year, and the peak current of the extracted H beam at the exit of the LEBT is expected to be 6 mA, with the output energy of 50 keV, maximum repetition rate of 0.5 Hz, beam pulse width of 10~40 microseconds and normalized RMS emittance of less than 0.2 PI mm mrad. Furthermore, the construction status of the RFQ accelerator and DTL accelerator will be presented in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPVA105  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPIK054 The X-Band Pulse Compressor for Tsinghua Thomson Scattering X-Ray Source 4214
 
  • Y.L. Jiang, H.B. Chen, C. Cheng, W. Gai, J. Shi, P. Wang, X.W. Wu, H. Zha
    TUB, Beijing, People's Republic of China
 
  An X-band (11.424 GHz) high-power RF station is being built for Tsinghua Thomson scattering X-ray Source (TTX). The station aims to feed several X-band accelerating structures working at a high gradient of 80 MV/m. An X-band pulse compressor is designed to compress the RF pulse from 1.5 us to 100 ns and to generate more than 250 MW peak power from a 50MW klystron. This pulse compressor implements a resonate cavity housing the HE11-mode as the energy storage cavity, with a high quality factor Q of more than 105. The detailed design of the high-Q cavity as well as the dedicate couplers of this pulse compressor are present in this work.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPIK054  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPIK058 Development of a S-Band Pulse Compressor 4227
 
  • P. Wang, H.B. Chen, C. Cheng, J. Shi, X.W. Wu, H. Zha
    TUB, Beijing, People's Republic of China
 
  We designed and fabricated a pulse compressor for S-band high power test stand at Tsinghua University. This pulse compressor is made up of a sphere resonant cavity with quality factor of 100000 and a rf polarizer. It has the ability of compressing a pulse from 3.6 us to 300 ns with the power gain of 7. A short description of the pulse compressor is presented, together with the RF design and low level RF measurement.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPIK058  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPIK059 Experimental Study on PM-AM Method in Pulse Compression System 4230
 
  • P. Wang, H.B. Chen, C. Cheng, M.M. Peng, J. Shi, X.W. Wu, J. Yang, H. Zha
    TUB, Beijing, People's Republic of China
 
  We experimentally demonstrate the PM-AM method (Phase Modulation to Amplitude Modulation) at the S-band high power test stand, which consists of two S-band klystrons, a SLED type pulse compressor and two high power stainless steel RF loads, in Tsinghua University. A LLRF (low level RF) system has been developed to modulate the phases of the two klystrons in real time such that pulse compressor could generate a flat output pulse. Experimental results presents that the efficiency of the pulse compression system is 45% and the power gain is 2.9.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPIK059  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)