Author: Chen, Y.
Paper Title Page
MOPVA025 Step-Like Field Magnets to Uniform Beam Distribution and Experiment at CADS Injector-I 908
 
  • C. Meng, Y. Chen, H. Geng, J.Y. Tang, F. Yan, L. Yu, Y.L. Zhao
    IHEP, Beijing, People's Republic of China
 
  High power is the development tendency of proton accelerator, so obtaining uniform beam distribution on target becomes more and more important and critical. The method of using step-like field magnets to obtain a uniform beam distribution on target was presented. In the beamdump line of CADS injector-I test facility four step-like field magnets have been installed to uniform beam distribution to reduce the maximum current density on the beamdump. The magnetic field of step-like field magnets have been measured and discussed in this paper. The simulation results and measurement results of beam uniformization are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA025  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)