Author: Budde, M.
Paper Title Page
THPVA077 Turn-Key Beamlines for the 15 - 30 MeV Medical Cyclotron at VECC 4631
 
  • C. Glarbo, M. Budde, F. Bødker, P.M. Hansen, M.N. Pedersen
    Danfysik A/S, Taastrup, Denmark
 
  Turn-key beamlines built by Danfysik are to be installed in 2017 at the medical cyclotron facility VECC in Kolkata, India. The beamlines will transport a 500 μA beam of 15 - 30 MeV protons to the target stations where they're used for the production of radioisotopes/radio-pharmaceuticals, and in research and development. A raster scanning system is used to generate an even dose distribution in a square or circular pattern. The beamline components, collimators, diagnostics, and helium cooled HAVAR separation foils protecting the beamlines and cyclotron from possible contamination from the targets are designed for the up to 15 kW beam power.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA077  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)