Author: Bødker, F.
Paper Title Page
TUPVA051 Magnets and Wien Filters for SECAR 2191
 
  • F. Bødker, N. Hauge, J. Kristensen
    Danfysik A/S, Taastrup, Denmark
  • G.P.A. Berg, M. Couder
    University of Notre Dame, Indiana, USA
  • H. Schatz
    NSCL, East Lansing, Michigan, USA
 
  The Separator for Capture Reactions, SECAR, is being built at Michigan State University for the study of low-energy capture reactions. The high performance magnets and two large Wien filters required to reach the very high recoil mass separation factor are being designed and produced at Danfysik to the SECAR specifications. The 2.4 m long Wien filters with a weight of 35 ton each including a large vacuum tank have high electrode voltages of ±300 kV combined with a magnetic field of 0.12 T. Challenging design requirements for integrated magnetic and electrostatic field homogeneity combined with tight tolerance on the effective lengths have been meet. The dipole magnets for this facility are special in having stringent ±0.5 mm effective magnetic length specifications in a wide excitation range and the transverse field boundary variation is described by a 4th order polynomial. Most of the dipoles are made with variable segmented field clamps in order to keep the deviation of the magnetic fringe field boundary within the required ±0.1 mm. The wide range of different quadrupole, sextupole and octupole magnets are required to meet the specified magnetic length with a tight tolerance.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPVA051  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPVA077 Turn-Key Beamlines for the 15 - 30 MeV Medical Cyclotron at VECC 4631
 
  • C. Glarbo, M. Budde, F. Bødker, P.M. Hansen, M.N. Pedersen
    Danfysik A/S, Taastrup, Denmark
 
  Turn-key beamlines built by Danfysik are to be installed in 2017 at the medical cyclotron facility VECC in Kolkata, India. The beamlines will transport a 500 μA beam of 15 - 30 MeV protons to the target stations where they're used for the production of radioisotopes/radio-pharmaceuticals, and in research and development. A raster scanning system is used to generate an even dose distribution in a square or circular pattern. The beamline components, collimators, diagnostics, and helium cooled HAVAR separation foils protecting the beamlines and cyclotron from possible contamination from the targets are designed for the up to 15 kW beam power.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA077  