Author: Sun, S.C.
Paper Title Page
THPOW041 Field Error Correction Considerations of Cryogenic Permanent Magnet Undulator (CPMU) for High Energy Photon Source Test Facility (HEPS-TF)* 4038
 
  • Y.F. Yang, H.H. Lu, S.C. Sun, X.Z. Zhang
    IHEP, Beijing, People's Republic of China
 
  Considerations are made for field error corrections of a 2m-long CPMU in built for HEPS-TF. Field changes in cooling to liquid nitrogen temperature are simulated. 1st field integral of terminal changes by tens of Gauss cm and RMS of phase errors induced by cold contraction is less than 1° when temperature gradient along girder is below 1.5K/m. Field signature of magic finger is unchanged with temperature. Strategy of the field error correction is discussed.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPOW041  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)