Author: Solyak, N.
Paper Title Page
TUPMY038 Preliminary Measurement of the Transfer Matrix of a TESLA-type Cavity at FAST 1632
 
  • A. Halavanau, P. Piot
    Northern Illinois University, DeKalb, Illinois, USA
  • N. Eddy, D.R. Edstrom, A. Lunin, P. Piot, J. Ruan, J.K. Santucci, J.K. Santucci, N. Solyak
    Fermilab, Batavia, Illinois, USA
 
  Funding: US Department of Energy (DOE) under contract DE-SC0011831 with Northern Illinois University. Fermilab is operated by the Fermi Research Alliance LLC under US DOE contract DE-AC02-07CH11359.
Superconducting linacs are capable of producing intense, ultra-stable, high-quality electron beams that have widespread application in Science and Industry. Many current and planned projects employ 1.3-GHz 9-cell superconducting cavities of the TESLA design*. In the present paper we discuss the transverse-focusing properties of such a cavity and non-ideal transverse-map effects introduced by field asymmetries in the vicinity of the input and high-order-mode radiofrequency (RF) couplers**. We especially consider the case of a cavity located downstream of an RF-gun in a setup similar to the photoinjector of the Fermilab Accelerator Science and Technology (FAST) facility. Preliminary experimental measurements of the CC2 cavity transverse matrix were carried out at the FAST facility. The results are discussed and compared with analytical and numerical simulations.
* A. Aunes et al., Phys. Rev.ST Accel. Beams 3, 092001 (2000).
** P. Piot, el. al., Proc. 2005 Part. Accel. Conf., Knoxville, TN, p. 4135 (2005).
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-TUPMY038  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMR011 Simulations and Experimental Studies of Third Harmonic 3.9 Ghz CW Couplers for LCLS-II Project 2280
 
  • N. Solyak, I.V. Gonin, E.R. Harms, S. Kazakov, T.N. Khabiboulline, A. Lunin
    Fermilab, Batavia, Illinois, USA
 
  LCLS-II linac is based on SRF technology developed for the XFEL project. The XFEL 3rd harmonic system built by INFN is based on the original designs of cavity and power coupler developed and built by Fermilab for the FLASH facility at DESY. For LCLS-II application both designs of the 3.9 GHz cavity and the power coupler have been modified for an operation in the continuous wave regime up to 2 kW average RF power. In this paper we discuss coupler modifications and the result multiphysics analysis for various operating regimes. For the initial test of a proposed design, we decided to modify two spare warm sections of power couplers, built for the FLASH facility, by shortening both of two inner bellows and making a thicker copper plating. Modification of the existing coupler test stand and the test program are briefly discussed in this paper.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPMR011  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMR012 Misalignment Studies of LCLS-II SC Linac 2283
 
  • A. Saini, N. Solyak, V.P. Yakovlev
    Fermilab, Batavia, Illinois, USA
  • T.O. Raubenheimer
    SLAC, Menlo Park, California, USA
 
  The Linac Coherent Light Source (LCLS) is an x-ray free electron laser facility. The proposed upgrade of the LCLS facility is based on construction of a 4 GeV superconducting (SC) linear accelerator (linac). An optimal reliable performance of the linac is largely determined by beam sensitivity to various component alignment errors. In this paper we evaluate misalignment tolerances of LCLSII SC linac using a more realistic alignment model that includes correlated misalignment of elements.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPMR012  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMR013 Study of LCLS-II Fundamental Power Coupler Heating in HTS Integrated Cavity Tests 2286
 
  • N. Solyak, I.V. Gonin, A. Grassellino, C.J. Grimm, T.N. Khabiboulline, J.P. Ozelis, K. Premo, O.V. Prokofiev, D.A. Sergatskov, G. Wu
    Fermilab, Batavia, Illinois, USA
 
  LCLS-II coupler based on modified design of TTF3 coupler for higher average power was assembled on high Q cavity and tested at HTS as part of integrated cavity test program. Couplers were thermally connected to thermal shields and equipped with diagnostics to control temperature in different locations and provide information about cryogenic heat loads at 2 K, 5 K and 80 K.Three dressed cavities with power couplers were tested in HTS at full specified RF power. Results are summarized in this paper and cross-checked with simulation.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPMR013  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMR003 Failure Modes and Beam Losses Studies in ILC Bunch Compressors and Main Linac 3388
 
  • A. Saini, N. Solyak, V.P. Yakovlev
    Fermilab, Batavia, Illinois, USA
 
  Proposed International linear collider (ILC) involves high average beam power. Dealing with high average beam power and smaller beam sizes result in stringent tolerances on beam losses and therefore, extensive studies are required to investigate every possible scenarios that lead to beam losses. In this paper we discuss beam losses due to failure of critical elements in beamline for ILC bunch compressors and main linac.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPMR003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)