Author: Nakamura, T.
Paper Title Page
MOPMB028 Development of Beam Diagnostic System for the SPring-8 Upgrade 149
 
  • H. Maesaka, T. Ohshima, Y. Otake
    RIKEN SPring-8 Center, Sayo-cho, Sayo-gun, Hyogo, Japan
  • H. Dewa, T. Fujita, K. Kobayashi, M. Masaki, S. Matsubara, T. Nakamura, S. Sasaki, S. Takano
    JASRI/SPring-8, Hyogo-ken, Japan
 
  The goal of the beam diagnostic system for the SPring-8 upgrade is to deliver brilliant X-rays enabled by the new low-emittance ring to experimental stations with ultimate stability. Developments of accurate electron and photon beam position monitors (EBPM and XBPM, respectively) with both short and long-term stability are the most critical. The EBPM sensitivity is also crucial for low-current beam commissioning to accomplish the first beam storage in the ring. We designed a button electrode to obtain sufficiently high-intensity signals while suppressing high-Q trapped modes leading to impedance and heating issues. We also designed a precise EBPM block and a rigid support to achieve mechanical accuracy and stability. Another challenge is the development of a reliable and stable XBPM, which should be an accurate reference for an orbit feedback without any photon-energy dependences. A significant improvement of a blade-type XBPM or an invention of a novel XBPM detecting the core of an intense X-ray beam are necessary. The other diagnostic instrumentations can be utilized for the new ring with minor improvements.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMB028  