MOOCB01 PACMAN Project: A New Solution for the High-accuracy Alignment of Accelerator Components 58
 
  • H. Mainaud Durand, K. Artoos, M.C.L. Buzio, D. Caiazza, N. Catalán Lasheras, A. Cherif, I.P. Doytchinov, J.-F. Fuchs, A. Gaddi, N. Galindo Munoz, J. Gayde, S.W. Kamugasa, M. Modena, P. Novotny, S. Russenschuck, C. Sanz, G. Severino, D. Tshilumba, V. Vlachakis, M. Wendt, S. Zorzetti
    CERN, Geneva, Switzerland
 
  The beam alignment requirements for the next generation of lepton colliders have become increasingly challenging. As an example, the alignment requirements for the three major collider components of the CLIC linear collider are as follows. Before the first beam circulates, the Beam Position Monitors (BPM), Accelerating Structures (AS)and quadrupoles will have to be aligned up to 10 μm w.r.t. a straight line over 200 m long segments, along the 20 km of linacs. PACMAN is a study on Particle Accelerator Components' Metrology and Alignment to the Nanometre scale. It is an Innovative Doctoral Program, funded by the EU and hosted by CERN, providing high quality training to 10 Early Stage Researchers working towards a PhD thesis. The technical aim of the project is to improve the alignment accuracy of the CLIC components by developing new methods and tools addressing several steps of alignment simultaneously, to gain time and accuracy. The tools and methods developed will be validated on a test bench. This paper presents the technical systems to be integrated in the test bench, the results of the compatibility tests performed between these systems, as well as the final design of the PACMAN validation bench.  
slides icon Slides MOOCB01 [9.553 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOOCB01  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOR017 A Micrometric Positioning Sensor for Laser-Based Alignment 2700
 
  • G. Stern, H. Mainaud Durand, D. Piedigrossi, M. Sosin
    CERN, Geneva, Switzerland
  • A. Geiger, S. Guillaume
    ETH, Zurich, Switzerland
 
  The Compact Linear Collider requires 10 μm accuracy over 200m for the alignment of its components. Since current techniques based on stretched wire or water level are difficult to implement, other options are under study. We propose a laser alignment system using positioning sensors made of camera/shutter assemblies. The goal is to implement such a positioning sensor. The corresponding studies comprise design and calibration as well as investigations of measurement accuracy and precision. On the one hand, we describe mathematically the laser beam propagation, its interaction with the shutter and image processing. On the other hand, we present experiments done with the prototype of a positioning sensor. As a result, we give practical suggestions to build the positioning sensors and we describe a calibration protocol to be applied to all sensors before measuring. In addition, we deliver estimates for measurement accuracy and precision. Our work provides the first steps towards a full alignment system.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOR017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOR018 Position Monitoring System for HL-LHC Crab Cavities 2704
 
  • M. Sosin, T. Dijoud, H. Mainaud Durand
    CERN, Geneva, Switzerland
  • V. Rude
    ESGT-CNAM, Le Mans, France
 
  The high luminosity upgrade for the LHC at CERN (HL-LHC project) will extend the discovery potential of the LHC by a factor 10. It relies on key innovative technologies like superconducting cavities for beam rotation, named 'crab cavities'. Two crab cavities will be hosted in a superconducting cryostat working at a cold (<3 K). The position of each cavity will be monitored during the cool-down and the operation in order to comply with the tight alignment tolerances: the misalignment of a cavity axis w.r.t. the other will have to be lower than 0.5 mm and each cavity roll w.r.t. the cryostat axis will have to be lower than 1 mrad. Moreover, the monitoring system will have to be radiation hard (up to 10 MGy) and maintenance free. We propose a solution based on the Frequency Scanning Interferometry to provide the position monitoring of the crab cavities. This paper describes the design and study of such a solution, including the engineering approach, the issues encountered and the lessons learnt.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOR018  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)