Author: Liang, C.C.
Paper Title Page
MOPMR034 Precise Betastron Tune Measurement in TPS Storage Ring 319
 
  • C.H. Chen, C.H. Chang, J.Y. Chen, M.-S. Chiu, S. Fann, C.H. Huang, T.Y. Lee, C.C. Liang, Y.-C. Liu, F.H. Tseng
    NSRRC, Hsinchu, Taiwan
 
  To acquire precise beam orbits from beam position monitors (BPMs) in storage ring is one of the most significant diagnosis to measure beam parameters. However, the precise spectrum analyses from BPM data acquisitions such as betatron tune, dynamics aperture and frequency map '..etc. that are depended on more accurate discrete Fourier transform (DFT) or the fast Fourier transform (FFT). A method of the fast Fourier transform correction (FFTc) was employed for the more accurate spectrum measurement in Taiwan Photon Source (TPS). We perform the accuracy and error analyses of this method from some spectral lines in two window functions. And the precise spectrum for betatron tune measurements and related results will be presented.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMR034  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPOR016 Impedance Study with Single Bunch Beam at Taiwan Photon Source 630
 
  • C.-C. Kuo, P.J. Chou, K.T. Hsu, K.H. Hu, C.C. Liang, C.Y. Liao, Z.K. Liu, H.-J. Tsai, F.H. Tseng
    NSRRC, Hsinchu, Taiwan
 
  The impedance at Taiwan Photon Source was investigated. The effects of bunch current such as a tune change, a synchronous phase shift and a bunch lengthening under operation conditions at various stages were measured; the machine impedances were deduced. This report presents the results with insertion devices in various configurations.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPOR016  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOW025 First Beam Test of the High Brightness Photo-injector at NSRRC 1800
 
  • A.P. Lee, M.C. Chou, N.Y. Huang, J.-Y. Hwang, W.K. Lau, C.C. Liang, M.T. Tsou
    NSRRC, Hsinchu, Taiwan
  • P. Wang
    NTHU, Hsinchu, Taiwan
 
  A High brightness injector at NSRRC is built for a VUV/THz free electron laser (FEL) facility and light source R&D. This injector with a photocathode rf gun with a solenoid for emittance compensation, a UV laser system, a 5.2 m S-band linac as well as various beam diagnostic tools has been installed in the linac test laboratory. The main goal is to produce beams with emittance smaller than 1 mm-mrad at energy of ~100 MeV. The other goal is to compress bunches to ~100 fs with charge of 100 pc and energy of ~30 MeV. In this contribution, an overview of the commissioning results of the photocathode rf gun and the laser system will be given. The first beam observation downstream the lianc will be presented in this paper.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-TUPOW025  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMB050 The Commmissioning of Phase-I Insertion Devices in TPS 3360
 
  • M.-S. Chiu, C.H. Chang, C.H. Chen, J. Chen, J.Y. Chen, Y.-S. Cheng, P.C. Chiu, P.J. Chou, T.Y. Chung, S. Fann, K.H. Hu, C.H. Huang, J.C. Huang, C.-S. Hwang, C.-C. Kuo, T.Y. Lee, C.C. Liang, Y.-C. Liu, H.-J. Tsai, F.H. Tseng, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  The Taiwan Photon Source (TPS) is a low-emittance 3-GeV light source at Natioal Synchrotron Radiation Research Center, next to the Taiwan Light source (1.5 GeV). On March 26, 2015, the TPS storage ring with two 5-cell PETRA cavities has successfully operated in 100 mA in top-up mode without the installation of insertion devices (IDs). To reach the design goal of 500 mA, the machine was shut down for 5 months to replace PETRA cavitites with superconducting RF (SRF) cavities and to install 10 IDs: 7 in-vacuum undulators (IU) and 3 elliptically polarized undulators (EPU). The commissioning of TPS storage ring with SRF cavities and IDs began in Sep. 2015. In this paper, we present our results and proceedures of ID commissioning.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPMB050  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMB051 Development of Intelligent Alarm Message System at TPS 3363
 
  • C.C. Liang, C.H. Chang, C.H. Chen, J. Chen, J.Y. Chen, Y.-S. Cheng, M.-S. Chiu, S. Fann, C.S. Huang, C.-C. Kuo, T.Y. Lee, Y.C. Lin, Y.-C. Liu, H.-J. Tsai, F.H. Tseng, I.C. Yang, T.-C. Yu
    NSRRC, Hsinchu, Taiwan
 
  The traditional alarm systems usually set up/low limit for various signals. When the acquired values exceed the limits, the alarm system would be activated. The proposed system in this article can focus on various possible events with many kinds of signals for response judgments. During alarm calling period, data can also be announced and recorded. The system can also monitor various events according to different time shifts. Integrating LabVIEW, mobile phone, AT-command and Bluetooth communication, the system can handle factory broadcast, sending E-mail and SMS message. The above sound and words messages can be set directly at the home-made software interface. The new intelligent alarm system can eliminate the procedure made by man with the added event recording, system stability improvement and debugging function in wider application fields.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPMB051  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)