Author: LeBlanc, G.
Paper Title Page
TUPOR023 Investigation of Trapped Resonant Modes in Insertion Devices at the Australian Synchrotron 1710
 
  • R.T. Dowd, M.P. Atkinson, M.J. Boland, G. LeBlanc, Y.E. Tan
    SLSA, Clayton, Australia
  • D. Teytelman
    Dimtel, San Jose, USA
 
  The Australian Synchrotron light Source has 3 variable gap in-vacuum undulators (IVU) in the storage ring. Since installation, these devices have been the source of strong beam instabilities. These instabilities seem to behave as trapped resonant modes of very high Q and high frequency, although a definite source has not been identified. The presence of these instabilities has necessitated operating at unusually high chromaticity for much of the light source's operations. More recently transverse feedback has been able to control the instabilities and recent developments in diagnostics have allowed some investigation of the frequency and mode response of these resonances. The results of this investigation will be presented in this paper.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-TUPOR023  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)