Author: Janezic, E.
Paper Title Page
MOPMR018 Beam Position Monitor for Circular Proton Accelerators 267
 
  • M. Žnidarčič, E. Janezic
    I-Tech, Solkan, Slovenia
  • K. Lang
    GSI, Darmstadt, Germany
 
  Position monitoring, tune calculation and subsequent optimization of hadron circular accelerators requires specific instrumentation. Libera Hadron is the newly developed instrument intended for data acquisition and post processing of signals from shoe-box or capacitive type pickups. Development, initial measurements and verification of the instrument performance were conducted in the Instrumentation Technologies' laboratories, followed by the characterization measurements of the unit carried out at Facility for Anti-proton and Ion Research (FAIR) facility. This article discusses the new BPM electronics concept, the tests performed and the performance obtained.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMR018  