Author: Gaupp, A.
Paper Title Page
THPOW038 First Results from Two Novel In-vacuum Magnetic Field Measurement Devices as Built at HZB 4028
 
  • J. Bahrdt, H.-J. Bäcker, J. Bakos, H. Bieder, W. Frentrup, A. Gaupp, S. Gottschlich, C. Kuhn, C. Rethfeldt, M. Scheer, B. Schulz
    HZB, Berlin, Germany
 
  The characterization of cryogenic in vacuum permanent magnet undulators with periods less than 20 mm and correspondingly narrow gaps requires new in-vacuum measurement systems. The positioning accuracy of the HZB in-vacuum Hallprobe bench has substantially been improved (a few μm) with appropriate feedback systems. A new in-vacuum cable tray has been developed. Another system for field integral measurements, an in-vacuum moving wire, is under commissioning. Both devices are presented.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPOW038  