Author: El Khaldi, M.
Paper Title Page
WEPOY024 Beam Dynamics Simulations of the Thomx Linac 3036
 
  • L. Garolfi, C. Bruni, M. El Khaldi, P. Lepercq, C. Vallerand
    LAL, Orsay, France
  • N. Faure
    PMB-ALCEN, PEYNIER, France
 
  ThomX Compton light source is designed to maximise the average X-ray flux providing a compact and tunable machine which can operate in hospitals or in museums. These constraints impose the choice of a high collision rate which is based on S-band Linac whose energy is 50-70 MeV combined to an electron storage ring. As most of the performances of the electron beam at the interaction point depend on the beam quality at the ring entrance, the linear accelerator must be carefully designed and especially the photo-injector. Simulations have been carried out in order to optimise the emittance for the ring entrance. Indeed, for a bunch charge of 1 nC, space charge effects usually dominate the total beam emittance. The latter can be minimized at the end of the Linac by means of emittance compensation. The best configuration across all the parameters will be presented.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOY024  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOW002 Electromagnetic, Thermal, and Structural Analysis of a THOMX RF Gun Using ANSYS 3925
 
  • M. El Khaldi, J. Bonis, A. Camara, L. Garolfi, A. Gonnin
    LAL, Orsay, France
 
  Photocathode RF guns are used in the first stage of electron beam generation and acceleration. The RF gun of THOMX is a 2.5 cell standing wave copper cavity with resonance frequency of 2998.55 MHz at 30 °C under vacuum. The metal photocathode such as copper or magnesium is inserted into the backplane of the cavity. Due to high repetition rates up to 50 Hz with the average dissipated power into the internal surfaces up to 1.5 kW, causing a heating and deformation of the cavity shape. Therefore, the cooling system of the device has to be well designed to take under control the deformations of the structure, providing a temperature increase as small and uniform as possible. For this purpose a fully coupled electromagnetic-thermal-structural finite element analysis on this gun has been performed with Ansys workbench. Numerical results show that the gun could operate at 3 μs RF pulse length and 50 Hz repetition rate with an average dissipated power of 1.5 kW. The gun average temperature is around 30 °C while the incoming water temperature is around 24°C. Internal speed of water is 2.5 m/s which corresponds to 15 l/min for the incoming water. The total pressure drop is around 0.4 bar  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPOW002  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)