Author: Du, Q.
Paper Title Page
THPOY059 Synchronization System for Tsinghua Thomson Scattering X-ray Source 4237
 
  • J. Yang, Y.-C. Du, W.-H. Huang, D. Wang, L.X. Yan
    TUB, Beijing, People's Republic of China
  • J.M. Byrd, L.R. Doolittle, Q. Du, G. Huang, R.B. Wilcox, Y.L. Xu
    LBNL, Berkeley, California, USA
 
  Tsinghua Thomson scattering X-ray Source (TTX) generates X-ray based on inverse thomson scattering method. The synchronization system for TTX includes reference distribution, normal conducting cavity Low Level RF control and Laser-RF synchronization. In collaboration with LBNL, we're working on a prototype synchronization system for TTX. Some test result based on Tsinghua Thomson scattering X-ray Source were obtained. In this paper we will show the synchronization system design and preliminary test result.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPOY059  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)