Author: Damjanovic, S.
Paper Title Page
THPMR043 Performance of Transverse Beam Splitting and Extraction at the CERN Proton Synchrotron in the Framework of Multi-turn Extraction 3492
 
  • G. Sterbini, J.C.C.M. Borburgh, S. Damjanovic, S.S. Gilardoni, M. Giovannozzi, C. Hernalsteens, M. Hourican, A. Huschauer, K. Kahle, G. Le Godec, O. Michels
    CERN, Geneva, Switzerland
  • C. Hernalsteens
    EPFL, Lausanne, Switzerland
 
  Considerable progress has been made in 2015 in the setting up of the multi-turn extraction (MTE) in the CERN Proton Synchrotron (PS). A key ingredient in this novel extraction technique is the beam splitting in transverse phase space. This manipulation is based on adiabatic trapping in stable islands of transverse phase space and requires mastering a number of devices in the PS ring. In addition, an in-depth review of all fast extractions schemes in the PS had been required due to the development and installation of a dummy septum to shield the actual magnetic septum. In this paper, the current performance of the beam splitting and of the extraction including the shadowing effect is presented. Future lines of development will also be discussed.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPMR043  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOY032 The Dual Use of Beam Loss Monitors at FAIR-SIS100: General Diagnostics and Quench Prevention of Superconducting Magnets 4167
 
  • S. Damjanovic, P. Kowina, C. Omet, M. Sapinski, M. Schwickert, P.J. Spiller
    GSI, Darmstadt, Germany
 
  In view of the planned coverage of the FAIR-SIS100 synchrotron with beam loss monitors (BLMs), FLUKA studies were performed aiming at two goals: i) evaluation of the sensitivity of the LHC-IC type detectors to the potential beam losses at SIS100; ii) estimation of the BLM quench prevention threshold via the correlation between the energy deposition inside the superconducting coils and the BLM active volume. A full spectrum of ion species and energies to be accelerated with SIS100 were considered in the simulations, showing a great sensitivity to the beam losses. An interesting finding of this study was that, for the same beam loss location, the quench prevention thresholds were almost identical for all ion species/energies including protons.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPOY032  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)