WEPMR020 First Cool-down of the Cornell ERL Main Linac Cryo-Module 2305
 
  • R.G. Eichhorn, J.V. Conway, F. Furuta, G.M. Ge, D. Gonnella, T. Gruber, G.H. Hoffstaetter, J.J. Kaufman, M. Liepe, T.I. O'Connell, P. Quigley, D.M. Sabol, J. Sears, E.N. Smith, V. Veshcherevich
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  Cornell University has finished building a 10 m long superconducting accelerator module as a prototype of the main linac of a proposed ERL facility. This module houses 6 superconducting cavities- operated at 1.8 K in continuous wave (CW) mode with a design field of 16 MV/m and a Quality factor of 2x1010. We wil shortly review the design and focus on reporting on the first cool-down of this module. We will giving data for various cool-down scenarios (fast/ slow), uniformity and performance  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPMR020  