Author: Chen, J.Y.
Paper Title Page
MOPMR034 Precise Betastron Tune Measurement in TPS Storage Ring 319
 
  • C.H. Chen, C.H. Chang, J.Y. Chen, M.-S. Chiu, S. Fann, C.H. Huang, T.Y. Lee, C.C. Liang, Y.-C. Liu, F.H. Tseng
    NSRRC, Hsinchu, Taiwan
 
  To acquire precise beam orbits from beam position monitors (BPMs) in storage ring is one of the most significant diagnosis to measure beam parameters. However, the precise spectrum analyses from BPM data acquisitions such as betatron tune, dynamics aperture and frequency map '..etc. that are depended on more accurate discrete Fourier transform (DFT) or the fast Fourier transform (FFT). A method of the fast Fourier transform correction (FFTc) was employed for the more accurate spectrum measurement in Taiwan Photon Source (TPS). We perform the accuracy and error analyses of this method from some spectral lines in two window functions. And the precise spectrum for betatron tune measurements and related results will be presented.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMR034  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMB049 Optics Calibration During Commissioning of the Taiwan Photon Source 3357
 
  • F.H. Tseng, C.H. Chen, J.Y. Chen, M.-S. Chiu, C.-C. Kuo, Y.-C. Liu, H.-J. Tsai
    NSRRC, Hsinchu, Taiwan
 
  The Taiwan Photon Source is a 3-GeV low emittance synchrotron light machine with circumference of 518.4m. The lattice is with 24-cell DBA structure and emittance is 1.6 nm-rad. During the commissioning in the past year, we employed MATLAB-based high level applications to calibrate the optical functions in three different operation lattice modes. In particular, we used LOCO (Linear Optics from Closed Orbit) to restore the machine optical functions and reduce emittance coupling ratio. The beam-based alignment (BBA) measurements as well as BPM and corrector errors were identified.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPMB049  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMB050 The Commmissioning of Phase-I Insertion Devices in TPS 3360
 
  • M.-S. Chiu, C.H. Chang, C.H. Chen, J. Chen, J.Y. Chen, Y.-S. Cheng, P.C. Chiu, P.J. Chou, T.Y. Chung, S. Fann, K.H. Hu, C.H. Huang, J.C. Huang, C.-S. Hwang, C.-C. Kuo, T.Y. Lee, C.C. Liang, Y.-C. Liu, H.-J. Tsai, F.H. Tseng, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  The Taiwan Photon Source (TPS) is a low-emittance 3-GeV light source at Natioal Synchrotron Radiation Research Center, next to the Taiwan Light source (1.5 GeV). On March 26, 2015, the TPS storage ring with two 5-cell PETRA cavities has successfully operated in 100 mA in top-up mode without the installation of insertion devices (IDs). To reach the design goal of 500 mA, the machine was shut down for 5 months to replace PETRA cavitites with superconducting RF (SRF) cavities and to install 10 IDs: 7 in-vacuum undulators (IU) and 3 elliptically polarized undulators (EPU). The commissioning of TPS storage ring with SRF cavities and IDs began in Sep. 2015. In this paper, we present our results and proceedures of ID commissioning.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPMB050  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMB051 Development of Intelligent Alarm Message System at TPS 3363
 
  • C.C. Liang, C.H. Chang, C.H. Chen, J. Chen, J.Y. Chen, Y.-S. Cheng, M.-S. Chiu, S. Fann, C.S. Huang, C.-C. Kuo, T.Y. Lee, Y.C. Lin, Y.-C. Liu, H.-J. Tsai, F.H. Tseng, I.C. Yang, T.-C. Yu
    NSRRC, Hsinchu, Taiwan
 
  The traditional alarm systems usually set up/low limit for various signals. When the acquired values exceed the limits, the alarm system would be activated. The proposed system in this article can focus on various possible events with many kinds of signals for response judgments. During alarm calling period, data can also be announced and recorded. The system can also monitor various events according to different time shifts. Integrating LabVIEW, mobile phone, AT-command and Bluetooth communication, the system can handle factory broadcast, sending E-mail and SMS message. The above sound and words messages can be set directly at the home-made software interface. The new intelligent alarm system can eliminate the procedure made by man with the added event recording, system stability improvement and debugging function in wider application fields.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-THPMB051  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)