Author: Ahn, T.S.
Paper Title Page
WEPOR039 Development of 200 MHz Digital LLRF System for the 1 MeV/n RFQ at KOMAC 2758
 
  • H.S. Jeong, T.S. Ahn, Y.-S. Cho, H.S. Kim, S.G. Kim, H.-J. Kwon
    Korea Atomic Energy Research Institute (KAERI), Gyeongbuk, Republic of Korea
  • Y.G. Song
    KAERI, Daejon, Republic of Korea
 
  KOMAC (Korea Multi-purpose Accelerator Complex) has a plan to develop the multipurpose ion irradiation system. This system includes the ion source, LEBT, RFQ and MEBT systems to transport ion particles to the target. In particular, the RFQ (Radio Frequency Quadrupole) system should receive 200 MHz RF within 1% amplitude error stability. To supply stable 200 MHz RF signal to the RFQ cavity, the LLRF (Low-Level Radio Frequency) system should be controlled through a control system which implemented using commercial digital board. This 1 MeV/n RFQ LLRF system has a concept to minimize the number of the analog components for minimizing the control error. For this, the FPGA (Field Programmable Gate Array) in the digital board will control the frequency of the output sinusoidal signal. In addition, this LLRF system applied the direct sampling, Non-IQ sampling, direct RF generation and fast IQ set update rate algorithm. In this presentation, the FPGA control logics of the LLRF digital board will be introduced. Also, the LLRF PI control logic test using 200 MHz dummy cavity will be described.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOR039  