Author: Nelson, J.
Paper Title Page
MOPWA058 Cavity Beam Position Monitor at Interaction Point Region of Accelerator Test Facility 2 807
 
  • Y.I. Kim, D.R. Bett, N. Blaskovic Kraljevic, P. Burrows, G.B. Christian, M.R. Davis, A. Lyapin
    JAI, Egham, Surrey, United Kingdom
  • S.T. Boogert
    Royal Holloway, University of London, Surrey, United Kingdom
  • J.C. Frisch, D.J. McCormick, J. Nelson, G.R. White
    SLAC, Menlo Park, California, USA
  • Y. Honda, T. Tauchi, N. Terunuma, J. Urakawa
    KEK, Ibaraki, Japan
 
  Nanometre resolution cavity beam position monitors (BPMs) have been developed to measure the beam position and linked to a feedback system control the beam position stability within few nanometres in the vertical direction at the focus, or interaction point (IP), of Accelerator Test Facility 2 (ATF2). In addition, for feedback applications a lower-Q and hence faster decay time system is desirable. Two IPBPMs have been installed inside of IP chamber at the ATF2 focus area. To measure the resolution of IPBPMs two additional C-band cavity BPMs have been installed one upstream and one downstream of the IP. One cavity BPM has been installed at an upstream image point of IP. The performance of the BPMs is discussed and the correlation between IP and image point positions is presented along with a discussion of using these BPMs for position stabilisation at the IP.