Author: Trinh, T.A.
Paper Title Page
MOPC031 Performance of a 13 MHz Cavity for an RF Implanter at PEFP* 136
 
  • T.A. Trinh
    UST, Daejeon, Republic of Korea
  • Y.-S. Cho, J.-H. Jang, D.I. Kim, H.S. Kim, H.-J. Kwon, B.-S. Park, K.T. Seol
    KAERI, Daejon, Republic of Korea
 
  Funding: This work is supported by the Ministry of Education, Science and Technology of the Korean Government
A 13 MHz - normal conducting cavity for an rf implanter has been successfully developed at PEFP (Proton Engineering Frontier Project). It consists of an inductive coil, accelerating electrodes and a ground electrode for the inductor. Quality factor of 2074 and critical coupling were achieved at resonant frequency of 12.658 MHz. Rf power of 1 kW was forwarded to the cavity without any spark in the cavity. Beam test was then carried out with a 27 keV helium beam generated from a Duoplasmatron ion source. The results showed that the helium beam was accelerated to final energy of 120 keV with energy spread of 1%. Detail experiments and results are addressed in this presentation.