Author: Tordeux, M.-A.
Paper Title Page
TUPC069 Bunch Length Measurements from the Incoherent Synchrotron Radiation Fluctuation at SOLEIL 1159
 
  • M.-A. Tordeux, F. Dohou, M. Labat, O. Marcouillé
    SOLEIL, Gif-sur-Yvette, France
 
  Bunch length measurements can be made by analysing the pulse to pulse intensity fluctuation of the incoherent synchrotron radiation as it has been reported elsewhere*. Such a method has been tested at SOLEIL for picosecond bunch durations, at several wavelengths and bandwidths in the visible range, using an avalanche photodiode. Thanks to the low-alpha optics the lengths of 10 μA bunches as short as 3 ps have been measured in good agreement with the streak camera results. We first used the radiation from a bending magnet, and then from a HU640 undulator that enhances the photon flux. Moreover, taking advantage of using the radiation from an undulator, we show that the method can still be used when the number of spikes emitted by the electron bunch is reduced to a few hundreds. This could be of interest for bunch length measurements of X-ray SASE FELs. Furthermore, we intend to use a single crystal diamond detector in order to perform these measurements in the X-ray range.
* F. Sannibale et al., "Absolute bunch length measurements by incoherent radiation fluctuation analysis", PRST AB 12, 032801 (2009).
 
 
WEPC050 New Optics for the SOLEIL Storage Ring 2124
 
  • P. Brunelle, F. Briquez, A. Loulergue, O. Marcouillé, A. Nadji, L.S. Nadolski, M.-A. Tordeux, J.F. Zhang
    SOLEIL, Gif-sur-Yvette, France
 
  SOLEIL, the French 2.75GeV synchrotron light source is delivering photons to 24 beam lines and is presently equipped with 22 insertion devices (ID) including a high field and small gap in-vacuum wiggler*. This paper presents the continuous work performed to reduce the strong non linear effects of several IDs. On one side, the ID defaults have been precisely identified using on-beam measurements, and magnetic correction developments are going on, especially for the in-vacuum wiggler and for the 10m long HU640 undulator. On the other side, a new optics has been optimised in terms of beta-functions (at the ID location) and non linear dynamics in order to improve the injection efficiency and the beam lifetime in the presence of IDs. The modified optics has been used daily in operation since November 2010 and ensures a beam lifetime greater than 10h for a 400mA stored beam with the users ID configuration. In parallel, an extensive experimental optimization has been performed to prepare the operation with an additional quadrupole triplet that provides double low vertical beta functions in one long straight section that will accommodate two canted in-vacuum insertion devices**.
* O. Marcouillé et al., IPAC10, p. 3102 (2010).
** A. Loulergue et al., IPAC10, p. 2496 (2010).
 
 
MOPS048 Microbunching Instability Studies at SOLEIL 709
 
  • C. Evain, J. Barros, J.B. Brubach, L. Cassinari, M.-E. Couprie, G. Creff, M. Labat, A. Loulergue, L. Manceron, R. Nagaoka, P. Roy, M.-A. Tordeux
    SOLEIL, Gif-sur-Yvette, France
 
  Microbunching instability arises in storage rings when the number of electrons in a bunch exceeds a threshold value. Its signature, i.e. a strong and irregular emission of Coherent Synchrotron Radiation (CSR) in the Terahertz (THz) domain, is studied at SOLEIL on the AILES infrared beamline, with the storage ring tuned in a low-alpha configuration (used to get shorter electron bunch). The comparison of this observed THz CSR with numerical simulations of the longitudinal electron bunch dynamics, permits to put in evidence that during the instability a modulation appears and drifts in the longitudinal profile of the electron bunch. The understanding of this instability is important as it limits some operation of the storage rings. Indeed the induced fluctuations prevent the use of THz on the far IR beamline at high current per bunch. And in normal alpha operation this instability may spoil the electron/laser interaction effects used to get femtosecond and/or coherent pulse in storage rings (with slicing, Coherent Harmonic Generation or EEHG schemes on storage ring).  
 
THPC044 Operation and Performance Upgrade of the Soleil Storage Ring 3002
 
  • A. Nadji, P. Brunelle, M.-E. Couprie, J.-C. Denard, J.-M. Filhol, J.-F. Lamarre, P. Lebasque, A. Loulergue, P. Marchand, L.S. Nadolski, R. Nagaoka, M.-A. Tordeux
    SOLEIL, Gif-sur-Yvette, France
 
  SOLEIL delivers photons to 24 beamlines. Up to 22 very diverse insertion devices (IDs) are now installed on the storage ring, and 4 more will come by summer 2011, including a Cryogenic undulator and an electromagnetic/permanent magnet helical undulator, both designed and built at SOLEIL. Work is continuing on beam dynamics and magnetic corrections to reduce the nonlinear effects of all these IDs. A new optics incorporating an additional quadrupole triplet in one long straight section has been successfully tested and will be put in operation by fall 2011. A new coupling correction will also be implemented to maintain the ratio of the vertical to the horizontal emittances at 1% for any IDs configuration. The electron beam orbit stability has been significantly improved reaching a residual noise of 300 nm RMS. Photon LIBERA modules of X-BPM located on the bends, will be integrated soon in the orbit feedback loops. 4905 hours have been delivered in 2010 to the beamlines with an availability of 96.3%. The user operation with the maximum current of 500 mA is foreseen to start by fall 2011, after the completion of the radiation safety tests of the beamlines.