Author: Tanabe, E.
Paper Title Page
THPS065 Upgraded X-band 950 KeV Linac X-ray Source for On-site Inspection at Petrochemical Complex 3574
 
  • M. Jin, K. Demachi, K. Dobashi, H.F. Jin, T. Natsui, M. Uesaka
    The University of Tokyo, Nuclear Professional School, Ibaraki-ken, Japan
  • J. Kusano, N. Nakamura, M. Yamamoto
    Accuthera Inc., Kawasaki, Kanagawa, Japan
  • E. Tanabe
    AET, Kawasaki-City, Japan
 
  Abstract―Our portable X-band (9.3GHz) 950KeV linac has been successfully upgraded. The problems of RF power oscillation, beam current oscillation and reduction and finally lack of X-ray intensity were solved by replacing the axial coupling cavities with the side-coupled ones. Designed X-ray dose rate of 0.05 Sv/min@1m is going to be achieved. Length of the accelerating tube is reduced to less than 25 cm. X-ray source part with the local radiation shielding is connected by the flexible waveguide with the box of the 300 kW magnetron and cooling unit. The total system consists of the three suit-case-size units, the last of which is one for the electric power supply. Even on-line dynamic transmission imaging is available by using the high intensity X-ray camera. Demonstration of the measurement of wall thinning of metal pipes with thick thermal shielding is under way. Updated measurement results will be presented. KEYWORDS: portable X-band linac X-ray source, on-site high energy X-ray inspection, petrochemical complex