THPC061 Comparison of Linear Optics Correction Means at the SLS 3032
 
  • M. Aiba, M. Böge, J.T.M. Chrin, N. Milas, T. Schilcher, A. Streun
    PSI, Villigen, Switzerland
 
  The experimental determination of linear optics is a fundamental prerequisite to achieving a high performance storage ring. In order to further enhance SLS performance and to simulataneously reveal the limitations of the various techniques, we perform a systematic study of linear optics optimization using various independent methods. These include an analysis of the orbit reponse (LOCO), turn-by-turn data, and the response of the tune, whose correction is accomplished using the standard SLS procedure of varying the quadrupole strengths. A comparison of results from these procedures, which use fully independent observables, provides us with a valuable cross-check. For example, the betatron phase advances between BPMs, which is independent of BPM calibration, confirms the optics correction as determined from LOCO. The linear optics are hence better optimized, and these procedures, LOCO in particular, further serve to expose any previously hidden mis-calibration of parameters e.g. from BPMs and corrector magnets. Systematic errors from turn-by-turn data could also be vastly reduced by a better synchronization of the BPM triggers with the electron beam.