Author: Prost, A.
Paper Title Page
THPS048 Design of Electrostatic Septa and Fast Deflector for MedAustron 3532
 
  • J. Borburgh, T. Fowler, A. Prost
    CERN, Geneva, Switzerland
  • T. Kramer, T. Stadlbauer
    EBG MedAustron, Wr. Neustadt, Austria
 
  For the MedAustron facility, under construction in Wiener Neustadt, three electric field deflectors are developed in collaboration with CERN. A fast deflector is used in the Low Energy Beam Transfer line to chop the beam. The chopped beam is swept onto a Faraday cup for measurement purposes and to stop beam being sent towards the synchrotron. Electrostatic septa are used for the multi turn injection of protons and ions as well as for the slow extraction from the synchrotron. Novel design features for MedAustron include an inversed cathode/anode support and high voltage feedthroughs rated at 150 kV. The possibility for a higher voltage will significantly improve the conditioning process of the septa surfaces. This paper describes the requirements of these devices as well as the mechanical design and strategies adopted for their power supplies.