WEPC172 Beam-induced Quench Test of a LHC Main Quadrupole 2388
 
  • A. Priebe, K. Dahlerup-Petersen, B. Dehning, E. Effinger, J. Emery, E.B. Holzer, C. Kurfuerst, E. Nebot Del Busto, A. Nordt, M. Sapinski, J. Steckert, A.P. Verweij, C. Zamantzas
    CERN, Geneva, Switzerland
  • A. Priebe
    EPFL, Lausanne, Switzerland
 
  Unexpected beam loss might lead to transition of a superconducting accelerator magnet to a normal conducting state. The LHC beam loss monitoring (BLM) system is designed to abort the beam before the energy deposited in the magnet coils reaches a quench-provoking level. In order to verify the threshold settings generated by simulation, a series of beam-induced quench tests at various beam energies have been performed. The beam losses are generated by means of an orbit bump peaked in one of the main quadrupole magnets. The analysis not only includes BLM data but also data from the electrical quench protection and cryogenic systems. The measurements are compared to Geant4 simulations of energy deposition inside the coils and corresponding BLM signal outside the cryostat. The results are also extrapolated to higher beam energies.  
 
THOAA03 Overview of LHC Beam Loss Measurements 2854
 
  • B. Dehning, A.E. Dabrowski, M. Dabrowski, E. Effinger, J. Emery, E. Fadakis, V. Grishin, E.B. Holzer, S. Jackson, G. Kruk, C. Kurfuerst, A. Marsili, M. Misiowiec, E. Nebot Del Busto, A. Nordt, A. Priebe, C. Roderick, M. Sapinski, C. Zamantzas
    CERN, Geneva, Switzerland
  • E. Griesmayer
    CIVIDEC Instrumentation, Wien, Austria
 
  The LHC beam loss monitoring system based on ionization chambers is used for machine protection, quench prevention and accelerator optimization. After one full year of operation it can be stated that its main functionality, that of the protection of equipment, has proven to be very robust with no issues observed for hundreds of critical beam loss events and the number of false beam aborts well below expectation. In addition the injection, dump and collimation system make regular use of the published loss measurements for system analysis and optimisation, such as the determination of collimation efficiency in order to identify possible intensity limitations as early as possible. Intentional magnet quenches have been performed to verify both the calibration accuracy of the system and the accuracy of the loss pattern predictions from simulations. Tests have also been performed with fast loss detectors based on single- and polycrystalline CVD diamond, which are capable of providing nanosecond resolution time loss structure. This presentation will cover all of these aspects and give an outlook on future performance.  
slides icon Slides THOAA03 [1.972 MB]