WEPC144 Beam Monitor Deformation by Tohoku Earthquake and its Recovery Project 2328
 
  • A. Miura, K. Hasegawa, H. Oguri, N. Ouchi
    JAEA/J-PARC, Tokai-mura, Japan
  • Z. Igarashi, M. Ikegami, T. Miyao
    KEK, Ibaraki, Japan
 
  On March 11, 2011, the biggest earthquake occurred at Tohoku and North Kanto area in Japan. This earthquake and related ones have attacked J-PARC accelerators and caused the big damage. As for the linac beam monitors, some commissioning tools which were installed in the linac had damage and the air leakage was observed. In the first step of the recovery work, we checked the damage and put the emergency treatment for vacuum of the cavities. All beam monitors were observed, the leak from the vacuum devices was tested and the conduction of the signal cables was measured to compare the previous performance. In the next step, we started to order the new devices which should be replaced and to obtain the calibration data. We found the leakage from the phase monitors. The earthquake caused the crack and deformation at the welded points between the metallic parts and ceramic parts. And a wire of the profile monitor was broken while the beam position monitors have no damage. We are continuing this recovery work ongoingly.  
 
WEPS095 Status of J-PARC Accelerator Facilities after the Great East Japan Earthquake 2727
 
  • K. Hasegawa, M. Kinsho, H. Oguri
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
  • T. Koseki
    KEK, Tokai, Ibaraki, Japan
 
  J-PARC was heavily affected by the March 11 Great East Japan Earthquake. When the earthquake struck, we had a beam study operation of the linac and the machine immediately stopped. Fortunately, we had no effects of tsunami that happened nearby and no one was injured. We can see subsidence at many places; about 1.5m over the wide area at the entrance of the linac building, about 50cm over the area of 1m x 10m at the main ring building, etc. Underground water is coming into the linac and the main ring tunnels. The water level at the linac reached a depth of 10 cm, but pumping with a diesel generator successfully saved from further flooding. At the RCS, the circulating road went wavy and the yard area for electricity and water devices was heavily distorted. Therefore, a high voltage power is not available on the date of abstract submission. We are investigating damages of each facility and also we are trying to estimate the beam restoration. The current status of the J-PARC accelerator facilities after the earthquake will be presented.