  A Hydrostatic Leveling System (HLS) has been installed at Diamond Light Source. 8 sensors have been positioned along a 60 metre portion of the floor of the Storage Ring and the Experimental Hall, stretching out along a typical beamline route from Insertion Device to sample. Results since June 2008 are presented comparing actual performance with the original specification as well as identifying movements associated with environmental factors.  
 
THPC071 Study of the Possibility of Implementing a Superbend in the Diamond Light Source 3059
 
  • R.P. Walker, N.P. Hammond, J. Kay, S.P. Mhaskar, B. Singh
    Diamond, Oxfordshire, United Kingdom
  • R. Bartolini
    JAI, Oxford, United Kingdom
 
  We report on recent studies of the feasibility and impact of replacing one of the regular 1.4 T bending magnets in Diamond with a normal conducting 3 T "Superbend" in order to enhance the hard X-ray output for a possible future beamline. We describe the preliminary magnet design, the engineering implications and the effect on beam dynamics, including the additional constraints that arise from implementing a superbend in a DBA lattice, as compared to the more common application in a TBA lattice.