TUPC130 Beam Test Performance of the Beam Position Monitors for the TBL Line of the CTF3 at CERN 1326
 
  • J.J. García-Garrigós, C. Blanch Gutierrez, J.V. Civera, A. Faus-Golfe
    IFIC, Valencia, Spain
  • S. Döbert
    CERN, Geneva, Switzerland
 
  Funding: Funding Agency: FPA2010-21456-C02-01
A series of Inductive Pick-Ups (IPU) for Beam Position Monitoring (BPM) with its associated electronics were designed, constructed and tested at IFIC. A full set of 16 BPMs, so called BPS units, were successfully installed in the Test Beam Line (TBL) of the CLIC Test Facility (CTF3) at CERN. In this paper we present the results of the beam test carried out on the BPS units of the TBL in order to determine their beam performances and check the specified operational requirements. We focus particularly on the position resolution parameter which is the BPS figure of merit according to TBL demands and is expected to reach the 5um resolution at maximum beam current (28A). The beam test results of the BPS units are also compared with the parameters from their previous characterization test at lab.