Author: Abs, M.
Paper Title Page
MOPC135 IFMIF-EVEDA RF Power System 394
 
  • D. Regidor, A. Arriaga, J.C. Calvo, A. Ibarra, I. Kirpitchev, J. Molla, P. Méndez, A. Salom, M. Weber
    CIEMAT, Madrid, Spain
  • M. Abs, B. Nactergal
    IBA, Louvain-la-Neuve, Belgium
  • P.-Y. Beauvais, M. Desmons, A. Mosnier
    CEA/DSM/IRFU, France
  • P. Cara
    Fusion for Energy, Garching, Germany
  • S.J. Ceballos, J. de la Cruz
    Greenpower Technologies, Sevilla, Spain
  • Z. Cvetkovic, Z. Golubicic, C. Mendez
    TTI, Santander, Spain
  • J.M. Forteza, J.M. González, C.R. Isnardi
    Indra Sistemas, San Fernando de Henares, Spain
  • D. Vandeplassche
    SCK-CEN, Mol, Belgium
 
  The IFMIF/EVEDA Accelerator Prototype will be a 9 MeV, 125 mA CW deuteron accelerator to validate the technical options for the IFMIF accelerator design. The Radiofrequency Quadrupole (RFQ), buncher cavities and Superconducting Radiofrequency Linac (SRF Linac) require continuous wave RF power at 175 MHz with an accuracy of ±1% in amplitude and ±1° in phase. Also the IFMIF/EVEDA RF Power System has to work under pulsed mode operation (during the accelerator commissioning). The IFMIF/EVEDA RF Power System is composed of 18 RF power generators feeding the eight RFQ couplers (200 kW), the two buncher cavities (105 kW) and the eight superconducting half wave resonators of the SRF Linac (105 kW). The main components of each RF power chain are the Low Level Radio Frequency system (LLRF), three amplification stages and a circulator with its load. For obvious standardization and scale economies reasons, the same topology has been chosen for the 18 RF power chains: all of them use the same main components which can be individually tuned to provide different RF output powers up to 200 kW. The studies and the current design of the IFMIF/EVEDA RF Power System are presented in this contribution.  
 
WEPS085 Deveopment of the IBA-JINR Cyclotron C235-V3 for Dmitrovgrad Hospital Center of the Proton Therapy 2706
 
  • E. Syresin, G.A. Karamysheva, M.Y. Kazarinov, S.A. Kostromin, N.A. Morozov, A.G. Olshevsky, V.M. Romanov, E. Samsonov, N.G. Shakun, G. Shirkov, S.G. Shirkov
    JINR, Dubna, Moscow Region, Russia
  • M. Abs, A. Blondin, P. Cahay, Y. Jongen, W.J.G.M. Kleeven, S. Zaremba
    IBA, Louvain-la-Neuve, Belgium
 
  The approval of the Dmitrovgrad project - the first Russian hospital center of the proton therapy was announced in 2010. The JINR-IBA collaboration have developed and constructed the proton cyclotron C235-V3 for this center. We plan to assemble this cyclotron in JINR in 2011 and perform tests with the extracted proton beam in 2012. This cyclotron is an essentially modified version of IBA C235 cyclotron. Modification of the extraction system is aim of new C235-V3 cyclotron. The new extraction system was constructed and tested. The experimentally measured extraction efficiency was improved from 60% for the old system to 77% for the new one. The new field mapping system was developed for the C235-V3 cyclotron. It system consists of the axial field mapping system and an additional system applied for radial field Br measurements. One of the goals of the cyclotron improvement is the modification of the sector spiral angle for reducing of coherent beam losses at acceleration. The coherent beam displacement from the median plane is defined by the vertical betatron tune Qz. An increase of the vertical betatron tune permits to reduce the coherent losses at proton acceleration.