Paper |
Title |
Page |
S04SRS02 |
A PC Based Control System for the CERN ISOLDE Separators |
162 |
|
- R. Billinge, A. Bret, I. Deloose, A. Pace, G. Shering
CERN, Meyrin, Switzerland
|
|
|
The control system of the two isotope separators of CERN, named ISOLDE, is being completely redesigned with the goal of having a flexible, high performance and inexpensive system. A new architecture that makes heavy use of the commercial software and hardware available for the huge Personal Computer (PC) market is being implemented on the 1700 geographically distributed control channels of the separators. 8 MS-DOS™ i386-based PCs with about 80 acquisition/control boards are used to access the equipments while 3 other PCs running Microsoft Windows™ and Microsoft Excel™ are used as consoles, the whole through a Novell™ Local Area Network with a PC Disk Server used as a database. This paper describes the interesting solutions found and discusses the reduced programming workload and costs that are expected to build the system before the start of the separators in March 1992.
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-ICALEPCS1991-S04SRS02
|
|
About • |
Received ※ 11 November 1991 — Accepted ※ 20 November 1991 — Issued ※ 04 December 1992 |
|
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
S13MMI02 |
General Man-Machine Interface Used in Accelerators Controls: Some Applications in CERN-PS Control Systems Rejuvenation |
452 |
|
- M. Boutheon, F. Di Maio, A. Pace
CERN, Geneva, Switzerland
|
|
|
A large community is now using Workstations as Accelerators Computer Controls Interface, through the concepts of windows - menus - synoptics - icons. Some standards were established for the CERN-PS control systems rejuvenation. The Booster-to-PS transfer and injection process is now entirely operated with these tools. This application constitutes a global environment providing the users with the controls, analysis, visualization of a part of an accelerator. Individual commands, measurements, and specialized programs including complex treatments are available in a homogeneous frame. Some months of experience in current operation have shown that this model can be extended to the whole project.
|
|