TOPB03 The Evolution of the ELETTRA Control System controls, booster, feedback, storage-ring 265
 
  • L. Pivetta, C. Scafuri
    ELETTRA, Basovizza, Trieste
  The evolution of the ELETTRA control system is presented by focusing on the major technical upgrades. The ElETTRA control system has been in operation since 1993. The orginal control system architecture was based on a three layer design. A field bus connected the low level computers used to interface the accelerator devices whilst a ten megabit shared Ethernet network linked the middle layer computers to the servers and operator workstations. A first control system upgrade started in 1998 in order to dismiss the field bus and to provide more computing power. A couple of years later a major rework of the network infrastructure was carried out with the introduction of a switched Ethernet architecture. Starting from 2003, in view of the construction of a new booster injector for the storage ring and of the FERMI@elettra free electron laser, new control system hardware and software platforms have been selected. Driven by the additional necessity of cutting development and maintenance costs, the Tango control system has been adopted. The tools developed in order to effectively manage the integration and coexistence of the legacy and new control system are described.  
slides icon Slides