Lim Jae-Hong
TUP59
Design of X-ray ionization beam profile monitor for Korea-4GSR
191
The Insertion Device (ID) photon beam of a synchrotron can be contaminated with radiation from upstream and downstream bending magnets, causing position measurement errors in blade-type monitors. Beamlines of the low emittance storage ring are particularly sensitive to photon beam position variations, requiring more accurate measurements. To address this, we designed an ionization profile monitor to non-destructively measure the profile and position of the white undulator beam at Korea-4GSR without contamination. Leveraging the relatively large active area of readout devices suitable for small emittance beams we have designed a 1:1 mapping field to defocus photo-ions. Given that the defocusing field can induce errors due to vertical position, we propose a calibration method and validate it using particle tracking simulation.
  • W. Song, M. Chung
    Pohang University of Science and Technology
  • G. Hahn, H. Hyun, J. Lim, J. Kim, M. Seo, S. Kim, S. Lee, S. Hwang, Y. Park
    Pohang Accelerator Laboratory
Paper: TUP59
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-TUP59
About:  Received: 11 Sep 2024 — Revised: 11 Sep 2024 — Accepted: 12 Sep 2024 — Issue date: 11 Dec 2024