Tan Jocelyn
THP03
Design Choices for the Cryogenic Current Comparator for FAIR
487
The Cryogenic Current Comparator (CCC) is a superconducting SQUID-based device, which measures extremely low electrical currents via their azimuthal magnetic field. Triggered by the need for nA current measurement of slow extracted beams and weak beams of exotic ions in the storage rings at FAIR and CERN, the idea of the CCC as a diagnostics instrument has been revitalized during the last ten years. The work of a collaboration of institutes specialized on the various subtopics resulted in a large variety of CCC types with respect to field-pickup, magnetic shielding, SQUID types and SQUID coupling. Many of them have been tested under laboratory and under beamline conditions, which formed a detailed picture of the application possibilities for CCCs in accelerators. In parallel to CCC detector development the cryogenic support system has steadily been optimized, to fulfil the requirement of a standalone liquid helium cryostat, which is nonmagnetic, fit for UHV application, vibration damped, compact and accessible for maintenance and repair. We present the major development steps of the CCC for FAIR. The latest beamtime results are shown as well as recent tests with the cryogenic system. The most promising CCC type for FAIR is the so called Dual-Core CCC (DCCC), which runs two pickups in parallel with independent electronics for noise reduction. The magnetic shielding has an axial meander geometry, which provides superior attenuation of external magnetic noise.
  • T. Sieber, H. Bräuning, M. Schwickert, T. Stoehlker
    GSI Helmholtzzentrum für Schwerionenforschung GmbH
  • F. Schmidl
    Friedrich-Schiller-Universitaet Jena
  • G. Khatri, J. Tan, T. Koettig
    European Organization for Nuclear Research
  • L. Crescimbeni
    Friedrich-Schiller-Universität
  • M. Schmelz, R. Stolz
    Leibniz Institute of Photonic Technology
  • V. Tympel
    Helmholtz-Institut Jena
  • V. Zakosarenko
    Supracon AG
Paper: THP03
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-THP03
About:  Received: 04 Sep 2024 — Revised: 10 Sep 2024 — Accepted: 10 Sep 2024 — Issue date: 11 Dec 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
THP11
Absolute beam current measurement for slow extracted beams at CERN's North Area facility
508
The North Area facility (NA), built in the 1970s at CERN, hosts several secondary beam lines for a large variety of physics experiments: Neutrino Platform, Dark matter, high energy physics, R&D, detector validation etc. 400 GeV/c primary proton beams, extracted from the SPS ring, are split along the transfer lines to fire on 4 targets and serve the users with secondary particles such as e-, e+, muons, pions, hadrons, kaons... Within a typical slow extraction scheme of 4.8 s, one gets a spill intensity of about 4E13 protons heading to the splitters. Available beam intensity monitors are ageing fast and are accurate up to 10% only, which is not compatible for future high intensity physics programs and new demanding specifications for the beam instrumentation. In the wake of the NA consolidation project, it is proposed to measure the beam intensity with a Cryogenic Current Comparator (CCC). Such devices installed at FAIR (GSI) and in the Antimatter Factory (CERN) have proven to be operational and having a resolution of a few nA. This paper describes the roadmap and challenges to come for the development of the new CCC.
  • J. Tan, G. Khatri, M. McLean, T. Koettig
    European Organization for Nuclear Research
  • F. Schmidl
    Friedrich-Schiller-Universitaet Jena
  • L. Crescimbeni
    Friedrich-Schiller-Universität
  • M. Schwickert, T. Sieber, T. Stoehlker
    GSI Helmholtzzentrum für Schwerionenforschung GmbH
  • V. Tympel
    Helmholtz-Institut Jena
Paper: THP11
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-THP11
About:  Received: 03 Sep 2024 — Revised: 09 Sep 2024 — Accepted: 09 Sep 2024 — Issue date: 11 Dec 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote