Author: Littleton, S.T.
Paper Title Page
TUP042 Nano-Amp Beam Current Diagnostic for Linac-to-ESA (LESA) Beamline 285
 
  • S.T. Littleton
    Stanford University, Stanford, California, USA
  • A.S. Fisher, C. Huang, T.O. Raubenheimer
    SLAC, Menlo Park, California, USA
 
  The LESA beamline is designed to transport dark current from the LCLS-II and LCLS-II-HE superconducting linacs to the End Station A for various fixed target experiments. The primary experiment is expected to be the Light Dark Matter eXperiment (LDMX) which required beam currents of a few pA. The operation of the beam line much be parasitic to the LCLS-II / LCLS-II-HE FEL operation. The dark current in the LCLS-II is expected to be at the nA-level which will be below the resolution of most of the LCLS-II diagnostics (it will be degraded before the experiments as necessary). This paper will describe a possible non-destructive diagnostic using synchrotron radiation that could be applied at multiple locations along the LCLS-II and the LESA beamline.  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-TUP042  
About • Received ※ 07 September 2023 — Revised ※ 11 September 2023 — Accepted ※ 13 September 2023 — Issue date ※ 16 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)