Author: Krouptchenkov, I.
Paper Title Page
MOP019 First Test with MicroTCA Based Cavity BPM Electronics for the European XFEL and FLASH 70
 
  • B. Lorbeer, H.T. Duhme, I. Krouptchenkov, T. Lensch, D. Lipka, M. Werner
    DESY, Hamburg, Germany
 
  The European X-ray free-electron laser (E-XFEL) and the FLASH2020+ project for the free electron laser Hamburg (FLASH) at DESY in Hamburg, Germany foresee several machine upgrades in the years to come. At FLASH a whole undulator section in a shutdown starting in summer 2024 and finishing in autumn 2025 is going to be rebuild. Existing button beam position monitors installed in this section of the machine do not deliver sufficient signal strength for future required resolution specification and orbit feedback optimization for machine operation. The resolution limitations will be overcome by replacing the button-based beam position monitors with in-house developed cavity beam position monitors and compact microTCA based radio frequency receiver read-out electronics. The measurement system has been tested and evaluated in a test setup at FLASH.  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-MOP019  
About • Received ※ 05 September 2023 — Revised ※ 08 September 2023 — Accepted ※ 21 September 2023 — Issue date ※ 30 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)